Instant 15-12E Instant Hot Water Pump

Technical data

Max Flow

6.6gpm

Max Head

39 feet

Max Input Power

45 W

Max Efficiency

23%

Voltage

220V

Insulation Class

H

Noise

42dB(A)

Protection Level

IP44

  • Item NO.:

    Instant 15-12E

Domestic heating and domestic water supply systems

Air conditioning systems

Industrial Circulation Systems

One button start: users touch the "start" button, the pump starts to run, when the water temperature reaches the upper limit of the set temperature or no flow in the pipeline when the pump stops running, after the start of the click on the "start"button can be turned off the pump again.

 

Timing function: The current time is in the set time period, if the water temperature is lower than the set temperature limit, the pump starts to run, when the water temperature reaches the set temperature limit or no flow in the pipeline when the pump stops running.

 

All-day mode function:If the water temperature is lower than the lower limit of the set temperature, the pump starts to run, when the water temperature reaches the upper limit of the set temperature or there is no flow in the pipeline, the pump stops running.

 

Tap start introduction: lift the tap for about l second, the pump starts to run,when the water temperature reaches the upper limit of the set temperature or there is no flow in the pipeline, the pump stops running, or runs continuously for3min to less than the upper limit of the set temperature when the pump stops running.

Conditions of use (shaft kept horizontal)

Use medium: fresh water or water +glycol(50%) mixture

Medium Water Temperature:0~80

Ambient temperature:0~+40.

Inlet pressure:>0.05bar

Media hardness: 25°dH

Relative humidity of the air: 95% maximum

 

Installation Drawing

To install Instant 15-12E Series Electric Pump, the arrow on the pump casing indicates the direction of liquid flow through the pump body.

When mounting the electric pump in line, the inlet and outlet shall be fitted with the two gaskets provided.

The electric pump shaft must be in a horizontal position when installed.

SPA15-12E Installation Drawing

 

SPA15-12E Performance Curve

Leave A Message
If you are interested in Shinhoo Pumps and want to know more details, please leave a message here, we will reply you as soon as we can.
Submit

Related Products

High Efficiency Circulation Pump
Master D 25-4 High Efficiency Circulator Pump

Power supply voltage 220~240V 50/60Hz, AC Motor protection No external protection required IP class IP44 Insulation class H Humidity(RH) Max. 95% System pressure 1.0 MPa Compliance CE/ GS/ EMC/ LVD/RoHS/REACH Environment temperature 0~+40℃ Temperature class TF110 Liquid temperature -30~+110℃(Glycol up to 50%) ​

R290 All Inverter Circulation Pump for Heat Pump
Grand 25-15 Pro Heat Pump Circulator Pump

Power supply voltage 220V~240V,AC,Protective earth Motor protection        No external protection required IP class IP67 Insulation class          H Humidity(RH)  Max 95% System pressure 1.0 Mpa Compliance EMC/RoHS/REACH/TUV/CE/EEI/CCC Environment temperature -30℃~55℃ Temperature class TF 95 Liquid temperature -20~+95℃ Connection/Unions Molex/TE ​

High efficiency Pressure Centrifugal Pump
AHB-600 Pressure Centrifugal Pump

Max. Flow(L/min) 115 Rated flow(L/min) 50 Max. Head(m) 25 Rated head(m) 20 Inlet diameter (mm) 25 Outlet diameter(mm) 25 Input power(W) 880 Output Power(W) 600 ​

North America Circulation Pump
Mega 32-8 North America Circulation Pump

Motor protection No external protection required IP class IP44 Insulation class H Humidity(RH) Max. 95% System pressure 1.0 MPa Compliance CE/ GS/ EMC/ LVD/RoHS/REACH Environment temperature 0~+40℃ Temperature class TF110 Liquid temperature -30~+110℃ (Glycol up to 50%) Voltage/ Frequency 110/230V,60HZ Pump housing Cast iron/Stainless steel Energy(EEI) ≤0.23-Part2 ​

sanitary centrifugal pump
Z178 Standard efficiency gas boiler pump

  Model   U(V)/f(Hz)   Speed   Q(m³/h)   H(m)   P(W)   I(A) GPD15-4S Z178 230/50 III 2.0 4.0 65 0.28 II 1.2 3.0 50 0.22 I 0.8 2.0 32 0.15 GPD15-5S Z178 230/50 III 2.2 5.0 85 0.40 II 1.5 4.0 60 0.30 I 1.0 2.5 40 0.22 GPD15-6S Z178 230/50 III 2.5 5.7 100 0.45 II 1.8 4.5 70 0.35 I 1.0 2.5 55 0.25 GPD15-7S Z178 230/50 III 2.8 6.5 130 0.60 II 2.0 5.0 110 0.52 I 1.2 3.5 90 0.42  ​

3 phase circulation pump
Basic S 25-6S Low Energy Circulation Pump

Product model Basic S 25-6S; Basic S 25-6SQ Ambient temperature  0 ~+40 °C Temperature of pumped liquid  +2 ~ +110 °C Storage temperature  -30 ~ +55 °C Pumps with unions 1.0 MPa (10 bar) Pump housing cast iron, stainless-steel(N) Port to port length 130/180mm ​

most efficient circulator pump
Classic S 32-5 PWM High Efficiency Circulator Pump

Power supply voltage 220-240V 50/60Hz, PE Motor protection No external protection required IP class IP44 Insulation class H Humidity(RH) Max. 95% System pressure 1.0 MPa Compliance CE/ GS/ EMC/ LVD/RoHS/REACH Environment temperature 0~+40℃ Temperature class TF110 Liquid temperature -30~+110℃ (Glycol up to 50%) Voltage/ Frequency 230V/50HZ Pump housing Cast iron Energy(EEI) ≤0.23-Part2 ​

Three Speed Circulation Pump
Basic 25-9S Pro Three Speed Circulation Pump

Model Basic 25-9SXL-180 Pro /Basic 25-9SXL-220 Pro  Rated Voltage/Frequency 230V/50Hz Insulation class Class H IP class IP44 Noise Index ≤50dB(A) Max System Pressure 10bar(1.0 MPa) Medium liquid Clean water Certification CCC\GS\UL\CE\RoHS\REACH\EEI ​

electric wall hung boiler pump
GPA15-7.5 III Pro Z197 High efficiency electric wall hung boiler pump

Model U(V)/f(Hz) Head Q(m³/h) P(W) I(A) GPA15-7.5 III Z197 pro 230/50 7.5 2.6 60 0.50     7 2.4 52 0.45     6 2.2 39 0.35     5 2.1 33 0.30 ​

Mechanical Pump
AHB-751 Pressure Centrifugal Pump

Max. Flow(L/min) 125 Rated flow(L/min) 80 Max. Head(m) 30 Rated head(m) 20 Inlet diameter (mm) 32 Outlet diameter(mm) 32 Input power(W) 1250 Output Power(W) 750 ​

hydronic circulating pump
Grand 25-11 Heat Pump Circulator Pump

Rated Power 140W Max.flow 6.5m³/h Max head 11m Rated Current 1.09A Voltage/ Frequency 230V 50HZ/60HZ Pump housing Cast iron Pumped liquid Water Insulation class H Degree of Protection IP44 Liquid temperature range -30-95℃ Energy(EEI) ≤0.21-Part3 Max System Pressure 1.0MPa ​

R290 All Inverter Circulation Pump for Heat Pump
Master H 20-7 Heat Pump circulator pump

Power supply voltage 220V~240V,AC,Protective earth Motor protection        No external protection required IP class IP44 Insulation class          H Humidity(RH)  Max 95% System pressure 1.0 Mpa Compliance EMC/RoHS/REACH/TUV/CE/EEI Environment temperature -30℃~55℃ Temperature class TF 95 Liquid temperature 2~+95℃ Connection/Unions Shinhoo Standard/ Molex/TE ​

Need Help? Chat with us

Leave A Message
If you are interested in Shinhoo Pumps and want to know more details, please leave a message here, we will reply you as soon as we can.
Submit
Looking for Honor?
Contact Us #
+86 0551 62379807

Our hours

Mon 11/21 - Wed 11/23: 9 AM - 8 PM
Thu 11/24: closed - Happy Thanksgiving!
Fri 11/25: 8 AM - 10 PM
Sat 11/26 - Sun 11/27: 10 AM - 9 PM
(all hours are Eastern Time)

Home

Products

contact