Instant 15-12E Instant Hot Water Pump

Technical data

Max Flow

6.6gpm

Max Head

39 feet

Max Input Power

45 W

Max Efficiency

23%

Voltage

220V

Insulation Class

H

Noise

42dB(A)

Protection Level

IP44

  • Item NO.:

    Instant 15-12E

Domestic heating and domestic water supply systems

Air conditioning systems

Industrial Circulation Systems

One button start: users touch the "start" button, the pump starts to run, when the water temperature reaches the upper limit of the set temperature or no flow in the pipeline when the pump stops running, after the start of the click on the "start"button can be turned off the pump again.

 

Timing function: The current time is in the set time period, if the water temperature is lower than the set temperature limit, the pump starts to run, when the water temperature reaches the set temperature limit or no flow in the pipeline when the pump stops running.

 

All-day mode function:If the water temperature is lower than the lower limit of the set temperature, the pump starts to run, when the water temperature reaches the upper limit of the set temperature or there is no flow in the pipeline, the pump stops running.

 

Tap start introduction: lift the tap for about l second, the pump starts to run,when the water temperature reaches the upper limit of the set temperature or there is no flow in the pipeline, the pump stops running, or runs continuously for3min to less than the upper limit of the set temperature when the pump stops running.

Conditions of use (shaft kept horizontal)

Use medium: fresh water or water +glycol(50%) mixture

Medium Water Temperature:0~80

Ambient temperature:0~+40.

Inlet pressure:>0.05bar

Media hardness: 25°dH

Relative humidity of the air: 95% maximum

 

Installation Drawing

To install Instant 15-12E Series Electric Pump, the arrow on the pump casing indicates the direction of liquid flow through the pump body.

When mounting the electric pump in line, the inlet and outlet shall be fitted with the two gaskets provided.

The electric pump shaft must be in a horizontal position when installed.

SPA15-12E Installation Drawing

 

SPA15-12E Performance Curve

Leave A Message
If you are interested in Shinhoo Pumps and want to know more details, please leave a message here, we will reply you as soon as we can.
Submit

Related Products

booster water pump for home
GPA15-6F North America circulating pump

Power Supply Voltage 115V +6%/-10%,60Hz,PE   Motor Protection   the pump needs no external protection   Degree of Protection   IP42   Insulation Class   H   Relative Humidity(RH)   Max. 95%   System Load Bearing   1.0 MPa  ​

Three Speed Circulation Pump With Flange Connection
Basic 50-16SF Pro Three Phase High Flow Circulation Pump

Model  Basic 50-16SF  Pro Power  1300/1000/900W Max.flow  30m³/h Max head  16m Voltage/ Frequency  380V/50HZ Pump housing  Cast iron Pumped liquid  Water Insulation class  H Degree of Protection  IP44 Liquid temperature range  2~110℃ Max System Pressure  1.0Mpa ​

Horizontal Three-Speed Circulator Pump
Basic 20-35SZ Horizontal Three-Speed Circulator Pump

Voltage(V) 230/380 Power(W) 1300/1100/800 Max Flow(m³/h) 10 Insulation Class H Protection Class IP44 System Pressure(bar) 10 Noise Index ≤54dB(A) ​

High Efficiency Circulation Pump
LPA 20-6 High Efficiency Circulation Pump

Power supply voltage 230V 50/60Hz, PE Motor protection No external protection required IP class IP44 Insulation class H Humidity(RH) Max. 95% System pressure 1.0 MPa Compliance CE/ GS/ EMC/ LVD/RoHS/REACH Environment temperature 0~+40℃ Temperature class TF110 Liquid temperature 2~+110℃ ​

sanitary centrifugal pump
Z178 Standard efficiency gas boiler pump

  Model   U(V)/f(Hz)   Speed   Q(m³/h)   H(m)   P(W)   I(A) GPD15-4S Z178 230/50 III 2.0 4.0 65 0.28 II 1.2 3.0 50 0.22 I 0.8 2.0 32 0.15 GPD15-5S Z178 230/50 III 2.2 5.0 85 0.40 II 1.5 4.0 60 0.30 I 1.0 2.5 40 0.22 GPD15-6S Z178 230/50 III 2.5 5.7 100 0.45 II 1.8 4.5 70 0.35 I 1.0 2.5 55 0.25 GPD15-7S Z178 230/50 III 2.8 6.5 130 0.60 II 2.0 5.0 110 0.52 I 1.2 3.5 90 0.42  ​

High Efficiency Circulation Pump
LPA 20-5 High Efficiency Circulation Pump

Power supply voltage 230V 50/60Hz, PE Motor protection No external protection required IP class IP44 Insulation class H Humidity(RH) Max. 95% System pressure 1.0 MPa Compliance CE/ GS/ EMC/ LVD/RoHS/REACH Environment temperature 0~+40℃ Temperature class TF110 Liquid temperature 2~+110℃ ​

High Efficiency Circulator Water Pump
Master D 25-7 High Efficiency Circulator Pump

Power supply voltage 220~240V 50/60Hz, AC Motor protection No external protection required IP class IP44 Insulation class H Humidity(RH) Max. 95% System pressure 1.0 MPa Compliance CE/ GS/ EMC/ LVD/RoHS/REACH Environment temperature 0~+40℃ Temperature class TF110 Liquid temperature -30~+110℃(Glycol up to 50%) ​

Customized High Efficiency  Erp Flange Circulator Pump
Mega S 65-12F High Efficiency Erp Flange automotive booster Circulator Pump

Enclosure class IPX4D (EN 60529). Insulation class H. Supply voltage 1 × 230 V ± 10 % 50 Hz, PE Digital input PWM 0–10 V Analog input 4–20 mA.  0–10 W direct current Connection bus input Modbus RTU Leakage current Ileakage < 3.5 mА.  Leakage current is measured in accordance with EN 60335-1. EMC Standards applied: EN61000-3-2, EN61000-6-3, EN61800-3-3, EN55014-1 and EN55014-2 ​

High Efficiency Circulator Pump
Classic E 32-6 High Efficiency Circulator pump

Power supply voltage 220-240V 50/60Hz, PE Motor protection No external protection required IP class IP44 Insulation class H Humidity(RH) Max. 95% System pressure 1.0 MPa Compliance CE/ GS/ EMC/ LVD/RoHS/REACH Environment temperature 0~+40℃ Temperature class TF110 Liquid temperature -30~+110℃ (Glycol up to 50%)  ​

hot water pump for house
GPD 40-7.5SFC North America circulation pump

Pump Body Length 8 1/2 Feet Power  245W Max.flow  44 gpm Max head  26 Feet Current  2.2A Voltage/ Frequency  110V 60HZ Pump housing  Cast iron Pumped liquid  Water Insulation class  H Degree of Protection  IP44 Liquid temperature range  2-110℃ Max System Pressure  1.0MPA ​

hot water recirculating pump
Basic S 32-8S Low Energy Circulation Pump

Product model Basic S 32-8S Ambient temperature  0 ~+40 °C Temperature of pumped liquid  +2 ~ +110 °C Storage temperature  -30 ~ +55 °C Pumps with unions 1.0 MPa (10 bar) Pump housing cast iron, stainless-steel(N) Port to port length 180mm ​

Horizontal Three-Speed Circulator Pump
Basic 20-26SZ Horizontal Three-Speed Circulator Pump

Voltage(V) 230/380 Power(W) 1000/860/580 Max Flow(m³/h) 9 Insulation Class H Protection Class IP44 System Pressure(bar) 10 Noise Index ≤50dB(A) ​

Need Help? Chat with us

Leave A Message
If you are interested in Shinhoo Pumps and want to know more details, please leave a message here, we will reply you as soon as we can.
Submit
Looking for Honor?
Contact Us #
+86 0551 62379807

Our hours

Mon 11/21 - Wed 11/23: 9 AM - 8 PM
Thu 11/24: closed - Happy Thanksgiving!
Fri 11/25: 8 AM - 10 PM
Sat 11/26 - Sun 11/27: 10 AM - 9 PM
(all hours are Eastern Time)

Home

Products

contact