Horizontal Multistage frequency conversion centrifugal pump

F-AHM804T 3 Phase Horizontal Multistage frequency conversion centrifugal pump

Technical data

Maximum flow(m³/h)

12

Rating flow(m³/h)

8

Maximum head(m)

48

Rating head(m)

38

Inlet pipe diameter

RP1 1/2"

Outlet pipe diameter

NPT1 1/4"

Input powwer(KW)

1.8

IP class

IP42

  • Item NO.:

    F-AHM804T

1. The inside of the pump body adopts special coating, which is not easy to rust;

2. Large flow, compact structure design;

3. Environmental protection, beautiful appearance, convenient installation and reliable operation;

4. Pipeline installation, easy connection;

5. Compact structure, space-saving;

6. Low noise, long life.

1. It can realize closed-loop constant pressure automatic water supply control, and set it according to the pressure required by the user;

2. Automatic energy-saving operation: the water pump automatically adjusts the speed according to the water consumption of the user to ensure the stability of the system pressure and save water and electricity;

3. Protection functions: stall control, water shortage protection, high pressure alarm and other protection functions;

4. When no one is using water, it can control the pump to stop and automatically enter sleep, and when someone is using water, it can automatically start the pump to restore constant pressure water supply;

5. Incoming power self-starting function: when the pump suddenly cuts off the power during normal operation, and it can automatically restart and restore the constant pressure water supply function before the power failure after the power is received;

6. Easy installation and operation, low noise.

Working conditions:

1. Power supply: 1~220V/50Hz;

2. Maximum system pressure: 7bar;

3. Insulation class: F;

4. IP class: IP42;

5. Ambient temperature during work: -15℃~110℃;

6. The water pump system is suitable for transporting drinking water, hot water, condensed water, etc. The main application fields include water supply system, boiler supply water system, cooling water system, etc.

Product production process testing items:

1. Assembly workshop;

2. Parameter setting inspection testing of the whole pump;

3. The airtight performance test testing of the whole pump.

Model testing of the pump in the laboratory:

1. Hydraulic performance inspection testing of the whole pump;

2. Noise and vibration detection testing of the whole pump;

3. Constant humidity and heat testing of the whole pump;

4. High and low temperature performance testing of the whole pump;

5. Pump life testing .

Installation dimension drawing:

Installation dimension drawing

 

 

Performance Curve 

 

Leave A Message
If you are interested in Shinhoo Pumps and want to know more details, please leave a message here, we will reply you as soon as we can.
Submit

Related Products

Horizontal Multistage frequency conversion centrifugal pump
F-AHM403T 3 Phase Horizontal Multistage frequency conversion centrifugal pump

Maximum flow(m³/h) 8 Rating flow(m³/h) 4 Maximum head(m) 33 Rating head(m) 25 Inlet pipe diameter RP1 1/4" Outlet pipe diameter NPT1" Input powwer(KW) 0.8 IP class IP42 ​

Horizintal Multistage frequency conversion centrifugal pump
F-AHM404T 3 Phase Horizintal Multistage frequency conversion centrifugal pump

Maximum flow(m³/h) 8 Rating flow(m³/h) 4 Maximum head(m) 42 Rating head(m) 38 Inlet pipe diameter RP1 1/4" Outlet pipe diameter NPT1" Input powwer(KW) 0.98 IP class IP42 ​

Horizontal Multistage frequency conversion centrifugal pump
F-AHM405T 3 Phase Horizontal Multistage frequency conversion centrifugal pump

Maximum flow(m³/h) 8 Rating flow(m³/h) 4 Maximum head(m) 57 Rating head(m) 50 Inlet pipe diameter RP1 1/4" Outlet pipe diameter NPT1" Input powwer(KW) 1.35 IP class IP42 ​

Horizontal multistage frequency conversion centrifugal pump
F-AHM803T 3 Phase Horizontal multistage frequency conversion centrifugal pump

Maximum flow(m³/h) 12 Rating flow(m³/h) 8 Maximum head(m) 35 Rating head(m) 25 Inlet pipe diameter RP1 1/2" Outlet pipe diameter NPT1 1/4" Input powwer(KW) 0.8 IP class IP42 ​

 Horizontal Multistage frequency conversion centrifugal pump
F-AHM805T 3 Phase Horizontal Multistage frequency conversion centrifugal pump

Maximum flow(m³/h) 12 Rating flow(m³/h) 8 Maximum head(m) 59 Rating head(m) 45 Inlet pipe diameter RP1 1/2" Outlet pipe diameter NPT1 1/4" Input powwer(KW) 2.2 IP class IP42 ​

circulating pump wholesale
F-AHM1603T 3 Phase Horizontal Multistage Frequency conversion centrifugal pump

Maximum flow(m³/h) 26 Rating flow(m³/h) 16 Maximum head(m) 33 Rating head(m) 26 Inlet pipe diameter RP2" Outlet pipe diameter NPT1 1/2" Input powwer(KW) 1.8 IP class IP42  ​

Swimming Pool High Flow Circulation Pump
SP-550A Swimming Pool Circulation Pump

Power supply  220V, 50Hz single-phase AC Maximum system pressure  ≤0.3MPa Insulation class  B Protection level  IPX5 Ambient temperature during work  within the range of 0°C to 50°C The temperature of the conveying liquid  within the range of 5°C to 50°C Delivery liquid  clear water ​

High Efficiency Circulation Pump
LPA 20-4 High Efficiency Circulation Pump

Power supply voltage 230V 50/60Hz, PE Motor protection No external protection required IP class IP44 Insulation class H Humidity(RH) Max. 95% System pressure 1.0 MPa Compliance CE/ GS/ EMC/ LVD/RoHS/REACH Environment temperature 0~+40℃ Temperature class TF110 Liquid temperature 2~+110℃ ​

3 phase circulator pumps
Basic 20-5S Three Speed Circulation Pump

Model  Basic 20-5S/Basic 20-5SB/Basic 20-5SN/Basic 20-5SQ/Basic 20-5SP Power  85/60/40W Max.flow  2.8m³/h Max head  5m Current  0.4/0.3/0.22A Voltage/ Frequency  115/230V 50/60HZ Pump housing  cast iron, stainless steel body(N) ,copper body(B) ,Bronze(Q) and Plastic (P) Pumped liquid  Water Insulation class  H Degree of Protection  IP44 Liquid temperature range  2-110℃ Max System Pressure  1.0Mpa ​

Three Speed Circulation Pump With Flange Connection
Basic 50-16SF Three Speed Circulation Pump With Flange Connection

Model  Basic 50-16SF Power  1300/1000/900W Max.flow  28/26/24m³/h Max head  16.5/16/15m Voltage/ Frequency  220/380V 3pH 50HZ Pump housing  Cast iron Pumped liquid  Water Insulation class  H Degree of Protection  IP42 Liquid temperature range  2-110℃ Max System Pressure  1.0Mpa ​

Mega S 50-12F
Mega S 50-12F High Efficiency Erp Flange automotive booster Circulator Pump

Enclosure class IPX4D (EN 60529) Insulation class H Supply voltage 1 × 230 V ± 10 % 50 Hz, PE Digital input PWM 0–10 V Analog input 4–20 mA.  0–10 W direct current Connection bus input Modbus RTU Leakage current Leakage < 3.5 mА.  Leakage current is measured in accordance with EN 60335-1 EMC Standards applied: EN61000-3-2, EN61000-6-3, EN61800-3-3, EN55014-1 and EN55014-2 ​

Horizontal Multistage Centrifugal Pump
AHM-803T 3 Phase Horizontal Multistage Centrifugal Pump

Rated voltage 220V Rated head 28m Rated flow 8m³/h Maximum head 35m Maximum flow 15m³/h Insulation class F Design pressure 10bar Vibration <2.8mm/s Protection class IP54 Frequency 50Hz Rated current 6.55A Rated power 1100W Noise <62dB(A) Maximum power 1400W ​

Need Help? Chat with us

Leave A Message
If you are interested in Shinhoo Pumps and want to know more details, please leave a message here, we will reply you as soon as we can.
Submit
Looking for Honor?
Contact Us #
+86 0551 62379807

Our hours

Mon 11/21 - Wed 11/23: 9 AM - 8 PM
Thu 11/24: closed - Happy Thanksgiving!
Fri 11/25: 8 AM - 10 PM
Sat 11/26 - Sun 11/27: 10 AM - 9 PM
(all hours are Eastern Time)

Home

Products

contact