GPA15-7.5 III Pro Z178 High efficiency gas boiler pump

Technical data

Model

U(V)/f(Hz)

Head

Qm³/h

PW

I(A)

GPA15-7.5 III Z178 pro

230/50

7.5

2.6

60

0.50

 

 

7

2.4

52

0.45

 

 

6

2.2

39

0.35

 

 

5

2.1

33

0.30

  • Item NO.:

    GPA III Pro Z178

1. Apply to wall hung gas boiler system.

2. Transfer the electrical energy to hydraulic pressure.

3. Transfer the heating water.

4. Exhaust the air from HW system.

5. Suitable for wall hung gas boiler: 18kW, 24kW, 28kW, 31kW, etc..

1. Shinhoo wall hung gas boiler pump is composed of stator, rotor, shield cover, vent valve and so on.

2. Sealing: stator and rotor sealed up with stainless steel shield cover, integral structure sealed up with

3. heat-resisting rubber washer, rather than mechanical seal. This ensures no leakage.

4. Lubrication and cooling: use internal circulation, lubricated and cooled by circulated liquid.

5. Motor: Insulation Class is H. Internal thermal protector. Single speed and three speeds are available.

6. Protection Class: IP 42.

7. Venting: based on floating ball principle, an integrated air venting system can exhaust the air out of water

8. Automatically during liquid injecting and running.

9. NoiseThe noise of pump that works in a boiler with rated flow is less than 42 dB(A).

Parameters:

Model: GPA15-7.5 III Z178 pro

Integrated 5m, 6m, 7m & 7.5m head in one pump

Max. flow: 2.6 m³/h

Max. head: 7.5 m

Liquid temperature: 20-95℃

Max. Pressure: 3 bar

EEI≤0.20-part 3

 

Operation Condition

Power: AC230V, 50Hz

The minimum start-up and operation voltage: 175V.

Different voltage and frequency is available according to customer’s requirement . All performance curves in this catalogue are based on pumps with power supply of AC 230V, 50Hz.

The max. system pressure: 3 bar.

In order to avoid cavitation damage to the pump bearing, the minimum inlet pressure should be kept as below: 1bar.

Ambient temperature must be lower than liquid temperature, in order to aviod condensate water produced in the interior of stator.

Transmission fluid: Thin, clean, non-corrosive and non-explosive liquids, without any particle, fiber or mineral oil. Pump can not be used for transferring flammable liquids such as diesel, petrol and so on.

Dry running: Pump is lubricated by water, dry running must be no more than 10s.

 

Installation:

The axial direction of pump must be parallel to ground and the vent valve should be installed vertically.

The user should not tighten the nut of valve.

It should be correctly installed by professional person

integrated head wall hung gas boiler pumps

Control Plate:

Light

Pump Head

Power

5

5m

33W

6

6m

39W

7

7m

52W

7.5

7.5m

60W

PWM

5m -7.5m

33W – 60W

Press button shortly could change pump head.

Control principle: Under PWM control mode the pump is controlled by PWM (Pulse Width Modulation) signal 

Designed PWM signal frequency range: 40Hz to 4000Hz

PWM Input signal is used to give speed order. T adjusts speed command by adjusting the PWM duty cycle.

PWM Output signal is the feedback signal from pump and the frequency is fixed by 75Hz.

4 pump heads: 5m, 6m, 7m and 7.5m integrated in one pump

Energy efficiency index: EEI≤0.20-part3

Installation Drawing

wall hung gas boiler pump

 

eco sanitary supplies pump

Leave A Message
If you are interested in Shinhoo Pumps and want to know more details, please leave a message here, we will reply you as soon as we can.
Submit

Related Products

electric wall hung boiler pump
GPA15-7.5 III Pro Z108 High efficiency electric wall hung boiler pump

Model U(V)/f(Hz) Head Q(m³/h) P(W) I(A) GPA15-7.5 III Z108 pro 230/50 7.5 2.6 60 0.50     7 2.4 52 0.45     6 2.2 39 0.35     5 2.1 33 0.30 ​

integrated head wall hung gas boiler pumps
GPA15-7.5 III Pro Z027 High efficiency gas boiler pump

Model U(V)/f(Hz) Head Q(m³/h) P(W) I(A) GPA15-7.5 III Z027 pro 230/50 7.5 2.6 60 0.50     7 2.4 52 0.45     6 2.2 39 0.35     5 2.1 33 0.30 ​

wall mounted gas boiler pump
GPA15-7.5 III Pro Z106 High efficiency gas boiler pump

Model U(V)/f(Hz) Head Q(m³/h) P(W) I(A) GPA15-7.5 III Z106 pro 230/50 7.5 2.6 60 0.50     7 2.4 52 0.45     6 2.2 39 0.35     5 2.1 33 0.30 ​

electric wall hung boiler pump
GPA15-7.5 III Pro Z107 High efficiency electric wall hung boiler pump

Model U(V)/f(Hz) Head Q(m³/h) P(W) I(A) GPA15-7.5 III Z107 pro 230/50 7.5 2.6 60 0.50     7 2.4 52 0.45     6 2.2 39 0.35     5 2.1 33 0.30 ​

electric wall hung boiler pump
GPA15-7.5 III Pro Z197 High efficiency electric wall hung boiler pump

Model U(V)/f(Hz) Head Q(m³/h) P(W) I(A) GPA15-7.5 III Z197 pro 230/50 7.5 2.6 60 0.50     7 2.4 52 0.45     6 2.2 39 0.35     5 2.1 33 0.30 ​

electric wall hung boiler pump
GPA15-7.5 III Pro Z107 High efficiency electric wall hung boiler pump

Model U(V)/f(Hz) Head Q(m³/h) P(W) I(A) GPA15-7.5 III Z107 pro 230/50 7.5 2.6 60 0.50     7 2.4 52 0.45     6 2.2 39 0.35     5 2.1 33 0.30 ​

Swimming Pool High Flow Circulation Pump
SP-550A Swimming Pool Circulation Pump

Power supply  220V, 50Hz single-phase AC Maximum system pressure  ≤0.3MPa Insulation class  B Protection level  IPX5 Ambient temperature during work  within the range of 0°C to 50°C The temperature of the conveying liquid  within the range of 5°C to 50°C Delivery liquid  clear water ​

IE5 Horizontal Single Stage Pump
EPA25-23ZA IE5 Horizontal Single Stage Pump

Voltage AC 220V Max Flow 5.1m³/h Max Head 23m Communication PWM Power 440W IP Class IP56 Connector Chuck ​

pressure booster pump
MHI-1604Q 3 Phase Horizontal Multistage centrifugal pump

Rated voltage 380V Rated head 32m Rated flow 16m³/h Maximum head 48m Maximum flow 23m³/h Insulation class F Design pressure  10bar Vibration <2.8mm/s Protection clas IP54 Frequency 50Hz Rated current 4.52A Rated power 2200W Noise <63dB(A) Maximum power 3100W ​

High Efficiency Circulator Pump for heating&cooling system
Master SD 20-6 High Efficiency Circulator Pump

Model Master SD 20-6 130     Maximum flow (m³/h) 3.0 Maximum head(m) 6.0 EEI EEI≤0.20-Part2 Rated voltage   220-240V  AC Rated current  0.5 A Frequency 50/60Hz Maximum power  39 W Design pressure  1.0MPa Noise  ≤42dB(A) IP class  IP44 Insulation class  H  ​

R290 All Inverter Circulation Pump for Heat Pump
Grand 32-15 Pro Heat Pump Circulator Pump

Power supply voltage 220V~240V,AC,Protective earth Motor protection        No external protection required IP class IP67 Insulation class          H Humidity(RH)  Max 95% System pressure 1.0 Mpa Compliance EMC/RoHS/REACH/TUV/CE/EEI/CCC Environment temperature -30℃~55℃ Temperature class TF 95 Liquid temperature -20~+95℃ Connection/Unions Molex/TE ​

R290 All Inverter Circulation Pump for Heat Pump
Grand 32-17 Heat Pump Circulator Pump

Power supply voltage 220V~240V,AC,Protective earth Motor protection        No external protection required IP class IP44 Insulation class          H Humidity(RH)  Max 95% System pressure 1.0 Mpa Compliance EMC/RoHS/REACH/TUV/CE/EEI Environment temperature -30℃~55℃ Temperature class TF 95 Liquid temperature 2~+95℃ Connection/Unions Shinhoo Standard/ Molex/TE ​

Need Help? Chat with us

Leave A Message
If you are interested in Shinhoo Pumps and want to know more details, please leave a message here, we will reply you as soon as we can.
Submit
Looking for Honor?
Contact Us #
+86 0551 62379807

Our hours

Mon 11/21 - Wed 11/23: 9 AM - 8 PM
Thu 11/24: closed - Happy Thanksgiving!
Fri 11/25: 8 AM - 10 PM
Sat 11/26 - Sun 11/27: 10 AM - 9 PM
(all hours are Eastern Time)

Home

Products

contact