According to Shinhoo's statistics on the failure performance of water pumps sold in the heat pump market in the past five years, there are four main types of common failure modes of water pumps. Now we will analyze the causes of noise problems and provide solutions. Reasons (1): Shaft wear causes shield cover to be worn and damaged. There are two reasons for shaft wear, one is scale and the other ...
According to Shinhoo's statistics on the failure performance of water pumps sold in the heat pump market in the past five years, there are four main types of common failure modes of water pumps. Now we will analyze the causes of noise problems and provide solutions. Reasons (1): Burn-in caused by stuck or blocked rotor. Recommended solutions: 1. Use a filter to keep the water clean in the pipeline...
The heat pump system is based on the Carnot cycle-a reversible thermal cycle composed of two constant temperature processes and two adiabatic processes. It is high efficient heat transfer equipment. The heat pump system can draw low-taste heat from the air, water and soil and apply it to hot water and heating in daily life. According to the characteristics of the heat pump matching the water pump,...
The canned motor pump is absolutely leak-free. And the outside air will not be sucked under the negative pressure inside the pump. It is especially suitable for vacuum system operation; at the same time, it is suitable for high pressure, high melting point, high and low temperature media. The canned motor pump is compact in structure, small in size and light in weight; it has no cooling fan, low n...
In order to avoid and reduce the sudden damage of the canned motor pump, canned motor pump needs regular maintenance. Most canned motor pumps can be repaired once a year. The maintenance method of the canned motor pump is: disassemble the canned motor pump, clean up the various parts, and make an apparent inspection on them to see if there are any abnormalities. Then measure the dimensions of the ...
The canned motor pump is a sealless pump. The pump body and the drive motor are sealed in a pressure vessel filled with pumping medium. The pressure vessel is only statically sealed, and a wire set is used to provide a rotating magnetic field and drive the rotor. This structure eliminates the rotary shaft sealing device of the traditional centrifugal pump, so it can be completely leak-free.
Gas wall-hung boilers are the first choices for heating in more and more homes. Most users who have used wall-hung boilers know that wall-hung boilers need correct usage and regular maintenance to better serve our heating and provide us with better usage experience. As one of the core components of the wall-hung boiler, water pump provides a stable pressure and flow rate fo...
The water pump does not run after power supply on, it is called "locking", which is the most common situation of wall-hung boiler water pump. It often occurs after the wall-hung boiler has not been running for a long time. 1. Locate a large screw on the top of the water pump and use a large "one" screw to loosen it. Then use a suitable screw to loosen the inner shaft slowly. After you feel the jam...