Technical data

Power supply voltage

220V~240V,AC,Protective earth

Motor protection       

No external protection required

IP class

IP67

Insulation class         

H

Humidity(RH) 

Max 95%

System pressure

1.0 Mpa

Compliance

EMC/RoHS/REACH/TUV/CE/EEI/CCC

Environment temperature

-30℃~55℃

Temperature class

TF 95

Liquid temperature

2~+95℃

Connection/Unions

Shinhoo Standard/ Molex/TE

  • Item NO.:

    Grand 25-11 Pro

1. Domestic heating and water supply system

2. Air and ground source heat pump system

3.Air-conditioning system

4. Industrial hot water circulation system

5.Solar thermal system

6.Compatibility with R290 All Inverter Heat Pump

Scope of use

Air source heat pump combined supply system  

Product certification

The product meets the requirements of TUVCEEMCRoHSREACHEEI≤0.23-part3 certification

Advantage

Easy installation and operation

Equipped with Self Adapting mode AUTO (default setting), pump runs once the power is connected and adapts its performance according to actual system needs.

Control is effected by digital pulse-width modulation (PWM) low-voltage signal, enabling the pump to be used to meet different flow requirement in various systems.

Low noise and high comfort

Noise index: ≤42dB(A)

Low energy consumption

Lowest power consumption up to 6W

Multiple protection

With over-voltage and over-current protection

Eco-Design Benchmark

EEI≤0.20-Part 3

Quick release power plug

Start-up and stop the pump quickly.

 

Basic parameters

Maximum flow:5.5m³/h

Maximum head:11m

Rated flow:3.5m³/h

Rated head:7.5m

Rated voltage:220-240V AC

Rated current:1A

Frequency:50/60Hz

Maximum power:160W

Design pressure:1.0MPa

Noise:35dBA

Standby power:≤2W

Degree of protection:IP67

Surge current:5A

Temperature class:TF95

Weight of bare pump with wire:3kg±5%

Speed:12004950rpm

 

Media requirements

Medium: water or water + glycol (≤ 50%)mixture

Medium temperature : 2℃∼95℃

PH value of medium 6.5-8.5

Medium hardness 25°dH

Content of solid impurities in medium: diameter and length direction of solid impurities ≤ 0.1mm, and volume ratio ≤ 0.1%

 

Service environment requirements

The working environment temperature of the pump should be synchronized with themedium temperature of 2~95℃, as shown in the figure on the right (the maximum ethylene glycol concentration is 50%, that is, the medium The minimum temperature is -30℃)

Start and stop of pump

Starting time: the starting time of the water pump is less than 8S, the timefrom power on to reaching the maximum speed

In PWM mode, when starting from the stop state of the water pump (without powersupply), 90% of the maximum speed must be reached in at least 8 seconds

In PWM mode, start from standby mode and reach 90% of the maximum speed inat least 8 seconds

Shutdown time: the shutdown time of the water pump is less than 1 s, that is,the time from power failure to shutdown of the water pump

Performance curve

This performance curve is suitable for normal temperature water, such as pump fornon-water medium, the hydraulic performance of the pump will be reduced , therefore ,in the selection of pump, must consider the characteristics of the liquid medium

Power connection

Voltage220-240V AC(±10% )

Frequency50/60Hz

PWM input signal voltage4-24V

minimum input current4mA

PWM input signal frequency: 100-2000Hz

PWM output signal: collector open-drain output, must be connected to a pull-up resistor,the voltage is selected according to the signal acquisition range of the host computer

Installation Drawing

Grand 25-11 pro Installlation Drawing

Model

B1

B2

L1

L2

H1

H2

G

Grand 25-11Pro/130

50

100

130

65

162

125

1 1/2”

This performance curve is suitable for normal temperature water, if the pump is used for non-water medium, the hydraulic performance of the pump will be reduced , therefore, in the selection of pump, must consider the characteristics of the liquid medium.

Grand 25-11 Pro H-Q Performance CurveGrand 25-11 Pro H-Q Performance Curve

Performance curve under different duty cycles in PWM mode (for reference only

Grand 25-11 Pro  PWM H-Q Performance Curve

Grand 25-11 Pro PWM P-Q Performance Curve

Leave A Message
If you are interested in Shinhoo Pumps and want to know more details, please leave a message here, we will reply you as soon as we can.
Submit

Related Products

R290 All Inverter Circulation Pump for Heat Pump
Master H 25-9 Pro Heat Pump Circulator Pump

Power supply voltage 220~240V,AC,Protective earth Motor protection        No external protection required IP class IP44 Insulation class          H Humidity(RH)  Max 95% System pressure 1.0 Mpa Compliance EMC/RoHS/REACH/TUV/CE/EEI Environment temperature -30℃~55℃ Temperature class TF 95 Liquid temperature 2~+95℃ Connection/Unions Shinhoo Standard/ Molex/TE ​

R290 All Inverter Circulation Pump for Heat Pump
Master H 32-9 Heat Pump Circulator Pump

Power supply voltage 220V~240V,AC,Protective earth Motor protection        No external protection required IP class IP44 Insulation class          H  Humidity(RH) Max 95% System pressure 1.0 Mpa Compliance EMC/RoHS/REACH/TUV/CE/EEI Environment temperature -30℃~55℃ Temperature class TF 95 Liquid temperature 2~+95℃ Connection/Unions Shinhoo Standard/ Molex/TE ​

Household automatic hot water booster pump
PH-254 Hot Water Circulating Pump

Max. Flow(L/min) 100 Rated flow(L/min) 50 Max. Head(m) 15 Rated head(m) 10 Inlet diameter (mm) 40 Outlet diameter(mm) 40 Input power(W) 300 Output Power(W) 250  ​

hot water pump manufacturer
GPD 40-4SFC North America circulation pump

Pump Body Length 8 1/2 Feet Power  245W Max.flow  62 GPM Max head  14 Feet Current  2.2A Voltage/ Frequency  110V 60HZ Pump housing  Cast iron Pumped liquid  Water Insulation class  H Degree of Protection  IP44 Liquid temperature range  2-110℃ Max System Pressure  1.0MPA ​

Circulation Pump for Underfloor Heating
Mega 40-10F North America Circulator Pumps

Motor protection No external protection required IP class IP44 Insulation class H Humidity(RH) Max. 95% System pressure 1.0 MPa Compliance CE/ GS/ EMC/ LVD/RoHS/REACH Environment temperature 0~+40℃ Temperature class TF110 Liquid temperature -30~+110℃ (Glycol up to 50%) Voltage/ Frequency 110/230V, 60HZ Pump housing Cast iron/Stainless steel Energy(EEI) ≤0.23-Part2 ​

electric wall hung boiler pump
GPA15-7.5 III Pro Z107 High efficiency electric wall hung boiler pump

Model U(V)/f(Hz) Head Q(m³/h) P(W) I(A) GPA15-7.5 III Z107 pro 230/50 7.5 2.6 60 0.50     7 2.4 52 0.45     6 2.2 39 0.35     5 2.1 33 0.30 ​

automatic boosting pump
Basic 50-16F Circulation Pump With Flange Connection

Model  Basic 50-16F Power  1300W Max.flow  27m³/h Max head  16m Current  5.8A Voltage/ Frequency  230V 50HZ Pump housing  Cast iron Pumped liquid  Water Insulation class  H Degree of Protection  IP44 Liquid temperature range  2-110℃ Max System Pressure  1.0Mpa ​

electric wall hung boiler pump
GPA15-7.5 III Pro Z107 High efficiency electric wall hung boiler pump

Model U(V)/f(Hz) Head Q(m³/h) P(W) I(A) GPA15-7.5 III Z107 pro 230/50 7.5 2.6 60 0.50     7 2.4 52 0.45     6 2.2 39 0.35     5 2.1 33 0.30 ​

Horizontal multistage frequency conversion centrifugal pump
F-MHI803Q 3 Phase Horizontal multistage frequency conversion centrifugal pump

Maximum flow(m³/h) 12 Rating flow(m³/h) 8 Maximum head(m) 35 Rating head(m) 25 Inlet pipe diameter RP1 1/2" Outlet pipe diameter NPT1 1/4" Input powwer(KW) 0.8 IP class IP42 ​

Customized High Efficiency  Erp Flange Circulator Pump
Mega S 65-12F High Efficiency Erp Flange automotive booster Circulator Pump

Enclosure class IPX4D (EN 60529). Insulation class H. Supply voltage 1 × 230 V ± 10 % 50 Hz, PE Digital input PWM 0–10 V Analog input 4–20 mA.  0–10 W direct current Connection bus input Modbus RTU Leakage current Ileakage < 3.5 mА.  Leakage current is measured in accordance with EN 60335-1. EMC Standards applied: EN61000-3-2, EN61000-6-3, EN61800-3-3, EN55014-1 and EN55014-2 ​

electric wall hung boiler pump
GPA15-7.5 III Pro Z197 High efficiency electric wall hung boiler pump

Model U(V)/f(Hz) Head Q(m³/h) P(W) I(A) GPA15-7.5 III Z197 pro 230/50 7.5 2.6 60 0.50     7 2.4 52 0.45     6 2.2 39 0.35     5 2.1 33 0.30 ​

PFB 06-22 EC domestic water pressure booster pumps
PFB 06-22 EC Permanent magnet centrifugal booster pump

Max Flow 8.5m³/h Rated Flow 6m³/h Pressure 1.0MPa Noise index <58dB(A)(Max flow) Max Head 28m Rated Head 22m Insulation IP55 Weight 5.7kg±5% Voltage AC 220V/50Hz Max Input Power 700W Max Rotation Speed 5000rpm ​

Need Help? Chat with us

Leave A Message
If you are interested in Shinhoo Pumps and want to know more details, please leave a message here, we will reply you as soon as we can.
Submit
Looking for Honor?
Contact Us #
+86 0551 62379807

Our hours

Mon 11/21 - Wed 11/23: 9 AM - 8 PM
Thu 11/24: closed - Happy Thanksgiving!
Fri 11/25: 8 AM - 10 PM
Sat 11/26 - Sun 11/27: 10 AM - 9 PM
(all hours are Eastern Time)

Home

Products

contact