electric wall hung boiler pump
electric wall hung boiler pump
electric wall hung boiler pump
electric wall hung boiler pump
electric wall hung boiler pump

GPA15-7.5 III Pro Z108 High efficiency electric wall hung boiler pump

Technical data

Model

U(V)/f(Hz)

Head

Qm³/h

PW

I(A)

GPA15-7.5 III Z108 pro

230/50

7.5

2.6

60

0.50

 

 

7

2.4

52

0.45

 

 

6

2.2

39

0.35

 

 

5

2.1

33

0.30

  • Item NO.:

    GPA III Pro Z108

1. Apply to wall hung gas boiler system.

2. Transfer the electrical energy to hydraulic pressure.

3. Transfer the heating water.

4. Exhaust the air from HW system.

5. Suitable for wall hung gas boiler: 18kW, 24kW, 28kW, 31kW, etc..

1. Shinhoo wall hung gas boiler pump is composed of stator, rotor, shield cover, vent valve and so on.

2. Sealing: stator and rotor sealed up with stainless steel shield cover, integral structure sealed up with

3. heat-resisting rubber washer, rather than mechanical seal. This ensures no leakage.

4. Lubrication and cooling: use internal circulation, lubricated and cooled by circulated liquid.

5. Motor: Insulation Class is H. Internal thermal protector. Single speed and three speeds are available.

6. Protection Class: IP 42.

7. Venting: based on floating ball principle, an integrated air venting system can exhaust the air out of water

8. Automatically during liquid injecting and running.

9. NoiseThe noise of pump that works in a boiler with rated flow is less than 42 dB(A).

Parameters:

Model: GPA15-7.5 III Z108 pro

Integrated 5m, 6m, 7m & 7.5m head in one pump

Max. flow: 2.6 m³/h

Max. head: 7.5 m

Liquid temperature: 20-95℃

Max. Pressure: 3 bar

EEI≤0.20-part 3

Operation Condition

Power: AC230V, 50Hz

The minimum start-up and operation voltage: 175V.

Different voltage and frequency is available according to customer’s requirement . All performance curves in this catalogue are based on pumps with power supply of AC 230V, 50Hz.

The max. system pressure: 3 bar.

In order to avoid cavitation damage to the pump bearing, the minimum inlet pressure should be kept as below: 1bar.

Ambient temperature must be lower than liquid temperature, in order to aviod condensate water produced in the interior of stator.

Transmission fluid: Thin, clean, non-corrosive and non-explosive liquids, without any particle, fiber or mineral oil. Pump can not be used for transferring flammable liquids such as diesel, petrol and so on.

Dry running: Pump is lubricated by water, dry running must be no more than 10s.

Installation:

The axial direction of pump must be parallel to ground and the vent valve should be installed vertically.

The user should not tighten the nut of valve.

It should be correctly installed by professional person

 

circulation pump factory

Control Plate:

Light

Pump Head

Power

5

5m

33W

6

6m

39W

7

7m

52W

7.5

7.5m

60W

PWM

5m -7.5m

33W – 60W

 

Press button shortly could change pump head.

Control principle: Under PWM control mode the pump is controlled by PWM (Pulse Width Modulation) signal 

Designed PWM signal frequency range: 40Hz to 4000Hz

PWM Input signal is used to give speed order. T adjusts speed command by adjusting the PWM duty cycle.

PWM Output signal is the feedback signal from pump and the frequency is fixed by 75Hz.

4 pump heads: 5m, 6m, 7m and 7.5m integrated in one pump

Energy efficiency index: EEI≤0.20-part3

Installation Drawing

Wall hung Gas boiler pump

electric wall hung boiler pump

Leave A Message
If you are interested in Shinhoo Pumps and want to know more details, please leave a message here, we will reply you as soon as we can.
Submit

Related Products

integrated head wall hung gas boiler pumps
GPA15-7.5 III Pro Z027 High efficiency gas boiler pump

Model U(V)/f(Hz) Head Q(m³/h) P(W) I(A) GPA15-7.5 III Z027 pro 230/50 7.5 2.6 60 0.50     7 2.4 52 0.45     6 2.2 39 0.35     5 2.1 33 0.30 ​

wall mounted gas boiler pump
GPA15-7.5 III Pro Z106 High efficiency gas boiler pump

Model U(V)/f(Hz) Head Q(m³/h) P(W) I(A) GPA15-7.5 III Z106 pro 230/50 7.5 2.6 60 0.50     7 2.4 52 0.45     6 2.2 39 0.35     5 2.1 33 0.30 ​

gas boiler circulation pumps
GPA15-7.5 III Pro Z178 High efficiency gas boiler pump

Model U(V)/f(Hz) Head Q(m³/h) P(W) I(A) GPA15-7.5 III Z178 pro 230/50 7.5 2.6 60 0.50     7 2.4 52 0.45     6 2.2 39 0.35     5 2.1 33 0.30 ​

electric wall hung boiler pump
GPA15-7.5 III Pro Z107 High efficiency electric wall hung boiler pump

Model U(V)/f(Hz) Head Q(m³/h) P(W) I(A) GPA15-7.5 III Z107 pro 230/50 7.5 2.6 60 0.50     7 2.4 52 0.45     6 2.2 39 0.35     5 2.1 33 0.30 ​

electric wall hung boiler pump
GPA15-7.5 III Pro Z197 High efficiency electric wall hung boiler pump

Model U(V)/f(Hz) Head Q(m³/h) P(W) I(A) GPA15-7.5 III Z197 pro 230/50 7.5 2.6 60 0.50     7 2.4 52 0.45     6 2.2 39 0.35     5 2.1 33 0.30 ​

electric wall hung boiler pump
GPA15-7.5 III Pro Z107 High efficiency electric wall hung boiler pump

Model U(V)/f(Hz) Head Q(m³/h) P(W) I(A) GPA15-7.5 III Z107 pro 230/50 7.5 2.6 60 0.50     7 2.4 52 0.45     6 2.2 39 0.35     5 2.1 33 0.30 ​

Swimming Pool High Flow Circulation  Pump
SP-750A Swimming pool Circulation Pump

Power supply  220V, 50Hz AC Maximum system pressure  ≤0.3MPa Insulation class  B Protection level  IPX5 Ambient temperature during work  within the range of 0°C to 50°C The temperature of the conveying liquid  within the range of 5°C to 50°C Delivery liquid  clear water ​

Wall Hung Gas Boiler Pump
GPA15-7.5 III U Z107 Wall Hung Gas Boiler Pump

Maximum flow (m3/h) 2.3 Maximum head(m) 7.5 Rated flow rate (m3/h) 1 Rated head (m) 6 Voltage 220~240V AC Current 0.45A Frequency 50/60Hz Input power 60W Design pressure 0.3MPa Noise ≤42dB(A) Standy power ≤3W Protection grade IP44 Surge current <3A Temperature class TF95 Bare pump weight 1.3kg±5% ​

Shinhoo Mega 32-12
Mega 32-12 Energy Saving Circulation Pumps

Maximum flow 10 m³/h Maximum head 12m Rated flow 5.5m³/h Rated head 7.5m Rated voltage  AC 220-240V Rated current 1.2A Frequency 50/60Hz Maximum power 230 W Design pressure 1.0MPa Noise <40dB(A) Standby power ≤4W Degree of protection IP44 Surge current <10A Speed 1000~4900rpm Temperature class TF110 Weight of bare pump with wire 5kg±5%  ​

domestic hot water Single Phase Circulation Pump  With Flange Connection
Basic 40-12F Pro Single Phase High Flow Circulation Pump

Model  Basic 40-12F Pro Power  700W Max.flow  11m³/h Max head  14m Current  3.55A Voltage/ Frequency  220~240V/50HZ Pump housing  Cast iron Pumped liquid  Water Insulation class  H Degree of Protection  IP44 Liquid temperature range  2~110℃  Max System Pressure  1.0Mpa ​

Three Phase Three Speed Circulation Pump With Flange  Connection
Basic 65-18SF Pro Three Phase High Flow Circulation Pump

Model Basic 65-18SF Pro Maximum flow 37m³/h Rated flow rate 24m ³/ h Maximum head 17.5m Rated head 10.5m Input Power 1800w Ingress protection IP44 Noises Index(Rated flow point) <48dB(A) ​

Instant Hot Water Pump
SPA 15-12E Instant Hot Water Pump

Max Flow 20 l/min Max Head 12 m Max Input Power 45 W Max Efficiency 23% Voltage AC 220V Insulation Class H Noise <42dB(A) Protection Level IP44 ​

Need Help? Chat with us

Leave A Message
If you are interested in Shinhoo Pumps and want to know more details, please leave a message here, we will reply you as soon as we can.
Submit
Looking for Honor?
Contact Us #
+86 0551 62379807

Our hours

Mon 11/21 - Wed 11/23: 9 AM - 8 PM
Thu 11/24: closed - Happy Thanksgiving!
Fri 11/25: 8 AM - 10 PM
Sat 11/26 - Sun 11/27: 10 AM - 9 PM
(all hours are Eastern Time)

Home

Products

contact