The canned motor pump is a sealless pump. The pump body and the drive motor are sealed in a pressure vessel filled with pumping medium. The pressure vessel is only statically sealed, and a wire set is used to provide a rotating magnetic field and drive the rotor. This structure eliminates the rotary shaft sealing device of the traditional centrifugal pump, so it can be completely leak-free.
The water pump does not run after power supply on, it is called "locking", which is the most common situation of wall-hung boiler water pump. It often occurs after the wall-hung boiler has not been running for a long time. 1. Locate a large screw on the top of the water pump and use a large "one" screw to loosen it. Then use a suitable screw to loosen the inner shaft slowly. After you feel the jam...
AS one of the most famous water circulation pump factory,Shinhoo offers a very flexible standard program of component solutions, including circulator pumps, motors, cables, connectors, control systems, etc. These standard components can be mixed and matched to thousands of different product variants. So in most cases we are able to meet your requirements with standard solution. If our standard sol...
There are mainly four reasons that cause canned motor pump can not pump water 1. Water or air leakage in the pipeline: The nut may not be tightened tightly during installation. If the leakage is not serious, apply cement or cement slurry mixed with asphalt oil on the leaking or leaking place. Serious water leakage must be re-disassembled. 2. The water circulator...
The impeller is an important accessory of the canned pump, and its shape, size, processing technology, etc. have a decisive influence on the performance of the water circulator pump. The function of the impeller is to transfer the energy input from the prime mover to the liquid. There are three main structural forms of water pump impellers: those with front and rear cover plates are called closed ...
Heat pump is a device that transfers heat energy from a low-level heat source to a high-level heat source. It is a energy-saving high-efficiency device that makes full use of low-grade heat energy. It is a new energy technology that attracts much attention all over the world. As we all know, heat can be transferred spontaneously from high-temperature objects to low-temperature objects, but not in ...
Position: The backwater side of the main engine of heat pump system Installation Direction: Horizontally Note: Avoid excessive bends Attention: 1. Select the water pump with base slotted structure: Condensate will be generated inside the water pump during transporting low-temperature medium, and the slotted base can discharge the condensate in time to prevent the accumulation inside the wat...
The 2022 government work report states that the energy intensity target will be assessed within the 14th Five-Year Plan, with appropriate flexibility, and that new renewable energy and raw material use will not be included in the total energy consumption control. China has entered a new stage of development, and promoting "double carbon" is an urgent need to solve the outstanding problems of resou...